Posted by john womack on December 13, 2006, 7:57 pm
hi all
engine with intermitant heavy diesel knock, fault code p0216 injection start circuit out of nominal range.
diagnosed at stealers as injector pump.
replaced injector pump,cleaned out all pipe work &tank etc.
now left with slight diesel knock abovge 2000 rpm but fault code still p0216 .have tried with pump advanced & retarded . tried fuel ecu, blanking off egr valve. nothing obvious on live data ,does any body know if there are any soft ware updates or modifiecations or have I lost the plot. could this be a faulty pump
only data not happy with is amount off fuel injected per cycle .