Posted by Andrew west on September 14, 2005, 9:37 pm, in reply to "Update"
Hello Peter, the oxygen content looks too high to me,making the lambdas read lean & adjusting the injector duration accordingly.I normally use a current clamp to test the heater circuit on the lambda sensors, unless they are dificult to get on. Regards, Andrew