Replies Archived Message
Posted by Paul Mc Ewan on June 29, 2004, 6:06 pm, in reply to "Re: Citroen/Xsara/2002/HDi RHY Bosch EDC15 Non starter"
Hi guys, Checked again today, ignition on low pressure takes two to three seconds to reach 2.2 bar, then as soon as pump relay drops out ignition still on, pressure drops to zero,should it not hold? on cranking, again it will take a couple of seconds but will reach 2 bar, stop cranking relay is still in for 2 secs then pressure falls to zero again. Faulty pump?
|
Message Thread:
- Citroen Xsara 2002 HDi RHY Bosch EDC15 - Non starter - Paul Mc Ewan June 28, 2004, 10:41 am
- Replies - Sean Mc Gettigan June 28, 2004, 9:08 pm
- Replies - Ed Kaps June 28, 2004, 9:25 pm
- Replies - Paul Mc Ewan June 29, 2004, 6:06 pm
- Replies - Nigel Bennett June 30, 2004, 6:08 am
- Fixed - Paul Mc Ewan September 1, 2004, 7:20 pm
|
|