    Posted by Tony Sefton on September 13, 2006, 8:47 pm, in reply to "Re: Renault megan 1.9 turbo diesel s reg 1999 old engine"

    Hi John. The fault with the starter motors is caused due to arcing where the brushes contact the communtator, The ones that we have done have all had around 80-100,000 miles and had oil contamination. And when they are stripped down, you can actually see a bad spot on the communtator where the brushes don't touch properly. We have reconditioned the starter motors ourself to prove exactly what causes the problem. ( rather than just accepting that a faulty starter motor causes the problem ) And all that is normally required is for the commutator to be machined up, a new set of brushes, etc. But normally for good measure a new solenoid is fitted and sometimes a new drive. H.T.H.